G21D102N4

GILLIG CORPORATION Pdf Download PDF Report

Static Towing Test Data Form

Date: 2001-07-24
Personnel: SC, TS, EL
Temperature: 84

 

Inspect right front tow eye and adjoining structure.
Comments: No damage or deformation.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Welds verified.
Inspect left front tow eye and adjoining structure.
Comments: No damage or deformation.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Welds verified.
Inspect right rear tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
Inspect left rear tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
General comments of any other structure deformation or failure:
All four front pulls were completed to the full test load of 31,440 lbs. No damage or deformation occurred during testing.