SLC 32' CNG
DAIMLER CHRYSLER COMMERCIAL BUSES NA
|
Date | 2001-11-20 |
---|---|
Personnel | S.C. |
Temperature (°F) | 40 |
Humidity (%) | 55 |
Wind Direction | NW |
Wind Speed (MPH) | 8-12 |
Barometer (in.Hg) | 30.05 |
Test Results
Inspect tow equipment-bus interface | A safe and adequate connection was made between the bus and tow equipment. |
---|---|
Inspect tow equipment-wrecker interface | A safe and adequate connection was made between the toe equipment and wrecker. |
Towing Comments | A front lift tow was performed incorporating a hydraulic under lift. |
Description and location of any structural damage | |
General Comments | Manufacturer does not recommend towing from the rear. |