416.03

IKARUS USA, INC. Pdf Download PDF Report

Static Towing Test Data Form

Date: 1992-10-16
Personnel: B.L., B.R & D.F.
Temperature: 65

 

Inspect right front tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Deformation was observed during the 20 degree upward pull.
Inspect left front tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
Inspect right rear tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Tow eye was not damaged after 20 degree upward pull.
Inspect left rear tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
General comments of any other structure deformation or failure:
A 20 degree upward pull was performed to 38058 lbs. Both tow eyes and surrounding structure were inspected afterwards. The left tow eye was slightly bent and the structure began to separate from the frame. The test was terminated.