9201

FLXIBLE Pdf Download PDF Report

Static Towing Test Data Form

Date: 1992-12-03
Personnel: B.L., K.D., B.R. & S.C.
Temperature: 35

 

Inspect right front tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage noted.
Inspect left front tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
Inspect right rear tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage noted.
Inspect left rear tow eye and adjoining structure.
Comments: No damage noted
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
General comments of any other structure deformation or failure:
A tow at all positions was done successfully without any damage to front tow eyes. A weight of 28220 lbs was used. A center towing point was also tested on the rear. Agian, all positions were tested successfully, with no noted damage to tow point. Front tow eyes were bolted and torque was checked after each test. Rear tow point was welded and visually checked after each pull.