40TB102

GILLIG CORPORATION Pdf Download PDF Report

Static Towing Test Data Form

Date: 1992-11-20
Personnel: B.L., K.D., D.F., & B.R.
Temperature: 37

 

Inspect right front tow eye and adjoining structure.
Comments: All torques verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage noted.
Inspect left front tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
Inspect right rear tow eye and adjoining structure.
Comments: All torques verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage noted.
Inspect left rear tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
General comments of any other structure deformation or failure:
A static tow was completed with no noted damage to the tow eyes. A tow hook-up (test center's) was used and a test weight of 34380 lbs was applied in all test positions. Rear tow not recommeded by manufacturer.