40/102TB/S50

GILLIG CORPORATION Pdf Download PDF Report

Static Towing Test Data Form

Date: 1993-03-30
Personnel: K.D., S.C., B.R. and D.F.
Temperature: 50

 

Inspect right front tow eye and adjoining structure.
Comments: All pulls; torques verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: All pulls; no deformation or damage observed.
Inspect left front tow eye and adjoining structure.
Comments: All pulls; torques verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: All pulls; no deformation or damage observed.
Inspect right rear tow eye and adjoining structure.
Comments: All pulls; torques verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: All pulls; no deformation or damage observed.
Inspect left rear tow eye and adjoining structure.
Comments: All pulls; no deformation or damage observed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: All pulls; torques verified.
General comments of any other structure deformation or failure:
A weight of 33960 lbs was used for test. All four front pulls and all four rear pulls were completed to a total static test load of 33,960 lb. No deformatoin or damage was noted throughout the test. There are two tow hooks on the front, and two tow eys on the rear. All tests were performed with no visible damage to either sets of tow connections.