ARTICULATE

NEOPLAN USA CORPORATION Pdf Download PDF Report

Static Towing Test Data Form

Date: 1993-04-20
Personnel: B.L., B.R., & S.C.
Temperature: 70

 

Inspect right front tow eye and adjoining structure.
Comments: Tow eyes were welded to frame, no bolts.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage noted
Inspect left front tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
Inspect right rear tow eye and adjoining structure.
Comments: Tow eyes were welded to frame, no bolts.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Nothing unusual, appearedd normal.
Inspect left rear tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
General comments of any other structure deformation or failure:
A weight of 56250 lbs was used during test. all positions were completed, with no visible defects. The panel covering tow eyes, had to be drilled out and removed to do the 20 degree down position.