AN 340

NEOPLAN USA CORPORATION Pdf Download PDF Report

Performance Data Form

Date
1993-04-14

Personnel
B.L., S.C., & R.H.


Temperature (°F)
54

Humidity (%)
70

Wind Direction
SE

Wind Speed (mph)
4

Barometric Pressure (in.Hg)
30.0

Air Conditioning - OFF Yes
Ventilation Fans - ON HIGH Yes
Heater pump motor - OFF Yes
Defroster - OFF Yes
Exterior and Interior Lights - ON Yes
Windows and Doors - CLOSED Yes

Acceleration, Gradeability, Top Speed

Counter Clockwise Recorded Interval Times
Speed Run 1 Run 2 Run 3
10 mph 5.6 5.45 5.65
20 mph 13.65 12.86 13.02
30 mph 23.11 22.35 22.44
40 mph 41.78 41.02 40.16
Top Test
Speed (50 mph)
70.08 69.02 69.22
Clockwise Recorded Interval Times
Speed Run 1 Run 2 Run 3
10 mph 5.61 5.42 5.55
20 mph 13.08 13.41 13.34
30 mph 21.56 20.82 22.18
40 mph 34.74 33.55 35.74
Top Test
Speed (50 mph)
50.34 49.4 51.68