Date Test Miles Service Activity Downtime Hours
11-30-93 725 Emergency exit on 3 windows are coming unlatched on the durability track. Latches removed, rivets replaced and latches reinstalled. 1.0 1.0
11-30-93 725 Wheelchair lift door is coming unlatched on the durability track. Upper latch pin is worn. Latch removed and pin reinforced with 4" piece of 1/2" pipe. 1.0 1.0
12-17-93 1702 Wheelchair lift door is coming unlatched on the durability track. Upper anchor plate is worn. Plate rotated 180 degrees. 1.0 1.0
01-18-94 3800 Air conditioning line is rubbing the top of the radiator. Line wrapped with rubber. 0.25 0.25
01-18-94 3800 Upper radiator hose has a slight leak. Hose clamp tightened. 0.25 0.25
11-30-93 725 Rear exhaust pipe hanger is broken and bolts sheared off. Pipe hanger and bolts replaced. 0.75 0.75
01-18-94 3800 Rear tail pipe hanger is broken. Hanger welded/repaired. 0.25 0.25
01-18-94 3800 Hanger aft of the muffler is broken. Hanger welded/repaired. 0.25 0.25
12-16-93 1500 Center cross member between frame rails; welds on both frame rail interfaces broken. Cross member welded in place. 0.5 0.5
11-26-93 236 3/8" set screw came out of the wheelchair lift. Screw located and replaced. 0.5 0.5
12-03-93 1172 Front hanger bolt for the right rear leaf spring is broken. Bolt ordered. 12-15-93 wrong bolt received from manufacturer. Proper bolt purchased locally and installed. 312.5 1.5