FLXIBLE Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 1994-06-23
Run Number: 1
Personnel: R.L. & R.H.
Test Direction: CCW
Ambient Temperature (°F): 73
Humidity (%): 58
SLW (lbs): 38600
Wind Speed (mpg) & Direction: 0/Calm
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:26 9:26 93.3 93.4
ART #1 0 4:30 4:30 103.1 64.9
CBD #2 0 9:42 9:42 103.0 94.5
Art #2 0 4:28 4:28 104.7 67.4
CBD #3 0 9:34 9:34 105.9 88.5
Commuter 0 6:05 6:05 105.5 85.5
Total Fuel: 494.20000000000005 SCF
20 minute idle: 81.5 SCF
No Load Flow Rate at Idle = 30.03 SCFM No Load Flow Rate at Full Throttle = 15.9 SCFM
Heating Value = 1008.1 BTU/LB
Comments: none

Date: 1994-06-23
Run Number: 2
Personnel: R.L. & R.H.
Test Direction: CCW
Ambient Temperature (°F): 73
Humidity (%): 58
SLW (lbs): 38600
Wind Speed (mpg) & Direction: 0/Calm
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:30 9:30 95.7 88.4
ART #1 0 4:34 4:34 108.0 63.8
CBD #2 0 9:26 9:26 107.8 84.6
Art #2 0 4:33 4:33 109.8 63.5
CBD #3 0 9:40 9:40 109.9 84.1
Commuter 0 6:05 6:05 111.3 83.8
Total Fuel: 468.2 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: none

Date: 1994-06-23
Run Number: 3
Personnel: R.L. & R.H.
Test Direction: CCW
Ambient Temperature (°F): 73
Humidity (%): 58
SLW (lbs): 38600
Wind Speed (mpg) & Direction: 0/Calm
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:31 9:31 99.5 94.0
ART #1 0 4:33 4:33 107.4 63.7
CBD #2 0 9:31 9:31 110.0 83.0
Art #2 0 4:34 4:34 112.8 61.8
CBD #3 0 9:28 9:28 112.5 82.1
Commuter 0 6:06 6:06 112.3 85.1
Total Fuel: 469.70000000000005 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: none

Date: 1994-06-23
Run Number: 4
Personnel: R.L. & R.H.
Test Direction: CW
Ambient Temperature (°F): 75
Humidity (%): 55
SLW (lbs): 38600
Wind Speed (mpg) & Direction: 2/NW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:33 9:33 101.5 91.2
ART #1 0 4:40 4:40 111.6 63.0
CBD #2 0 9:38 9:38 113.7 84.3
Art #2 0 4:35 4:35 113.8 63.3
CBD #3 0 9:55 9:55 114.3 84.4
Commuter 0 6:05 6:05 113.5 87.5
Total Fuel: 473.70000000000005 SCF
20 minute idle: 60.6 SCF
No Load Flow Rate at Idle = 3.01 SCFM No Load Flow Rate at Full Throttle = 14.05 SCFM
Heating Value = 1008.1 BTU/LB
Comments: none