Static Towing Test Data Form
Date:
|
1995-01-04
|
Personnel:
|
B.L., S.C., & B.R.
|
Temperature:
|
15
|
Inspect right front tow eye and adjoining structure. |
Comments:
Welds OK.
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
No damage or deformation.
|
Inspect left front tow eye and adjoining structure. |
Comments:
N/A
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
N/A
|
Inspect right rear tow eye and adjoining structure. |
Comments:
Welds OK.
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
20 degree up & down - no damage or deformation. Tow eye deformed inward during 20 degree left pull terminating further testing. (Approx. 10,500 lbs.)
|
Inspect left rear tow eye and adjoining structure. |
Comments:
N/A
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
N/A
|
General comments of any other structure deformation or failure: |
The 20 degree up & down pulls were performed to the full static load of 34,740 lbs. with no deformation or damage observed. At a load of approximately 10,500 lbs. during the left pull, the right tow eye started to deform inward terminating further testing. |
|
|