TRANSMARK RE

ELDORADO NATIONAL

Fuel Economy Data (Gaseous Fuels)

Date: 1994-10-06
Run Number: 1
Personnel: B.L. & R.H.
Test Direction: CCW
Ambient Temperature (°F): 44
Humidity (%): 73
SLW (lbs): 28350
Wind Speed (mpg) & Direction: 4/SW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:41 9:41 46.1 96.8
ART #1 0 4:45 4:45 45.2 81.9
CBD #2 0 9:43 9:43 36.2 95.8
Art #2 0 4:43 4:43 47.2 81.0
CBD #3 0 9:35 9:35 38.1 92.2
Commuter 0 6:09 6:09 48.8 82.2
Total Fuel: 529.9 SCF
20 minute idle: 21.0 SCF
No Load Flow Rate at Idle = 1.1 SCFM No Load Flow Rate at Full Throttle = 25.16 SCFM
Heating Value = 1008.1 BTU/LB
Comments: none

Date: 1994-10-06
Run Number: 2
Personnel: B.L. & R.H.
Test Direction: CCW
Ambient Temperature (°F): 44
Humidity (%): 73
SLW (lbs): 28350
Wind Speed (mpg) & Direction: 4/SW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:36 9:36 58.5 96.3
ART #1 0 4:43 4:43 51.3 80.9
CBD #2 0 9:33 9:33 41.1 94.0
Art #2 0 4:48 4:48 59.1 79.5
CBD #3 0 9:38 9:38 46.0 91.9
Commuter 0 6:06 6:06 55.6 79.5
Total Fuel: 522.1 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: none

Date: 1994-10-06
Run Number: 3
Personnel: B.L. & R.H.
Test Direction: CW
Ambient Temperature (°F): 56
Humidity (%): 60
SLW (lbs): 28350
Wind Speed (mpg) & Direction: 3/WSW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:52 9:52 69.2 92.4
ART #1 0 4:45 4:45 60.1 75.9
CBD #2 0 9:42 9:42 51.2 89.6
Art #2 0 4:44 4:44 61.8 75.1
CBD #3 0 9:35 9:35 53.0 88.7
Commuter 0 6:09 6:09 59.9 76.8
Total Fuel: 498.5 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: none

Date: 1994-10-06
Run Number: 4
Personnel: B.L. & R.H.
Test Direction: CW
Ambient Temperature (°F): 56
Humidity (%): 60
SLW (lbs): 28350
Wind Speed (mpg) & Direction: 3/WSW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:37 9:37 70.8 90.6
ART #1 0 4:40 4:40 65.0 74.9
CBD #2 0 9:20 9:20 54.4 88.0
Art #2 0 4:42 4:42 63.8 74.2
CBD #3 0 9:24 9:24 57.5 87.7
Commuter 0 6:10 6:10 66.4 76.3
Total Fuel: 491.7 SCF
20 minute idle: 20.8 SCF
No Load Flow Rate at Idle = 1.1 SCFM No Load Flow Rate at Full Throttle = 24.6 SCFM
Heating Value = 1008.1 BTU/LB
Comments: none