UDTV-29

NORTH AMERICAN TRANSIT, INC.

Fuel Economy Data (Gaseous Fuels)

Date: 1995-01-18
Run Number: 1
Personnel: B.L. & R.H.
Test Direction: CCW
Ambient Temperature (°F): 38
Humidity (%): 80
SLW (lbs): 18400
Wind Speed (mpg) & Direction: 5/SW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:01 9:01 40.0 64.4
ART #1 0 4:15 4:15 43.1 62.7
CBD #2 0 9:04 9:04 35.1 60.3
Art #2 0 4:18 4:18 46.9 60.7
CBD #3 0 9:20 9:20 38.3 61.5
Commuter 0 6:00 6:00 46.8 70.3
Total Fuel: 379.90000000000003 SCF
20 minute idle: 41.5 SCF
No Load Flow Rate at Idle = 2.03 SCFM No Load Flow Rate at Full Throttle = 27.95 SCFM
Heating Value = 1008.1 BTU/LB
Comments: none

Date: 1995-01-18
Run Number: 2
Personnel: B.L. & R.H.
Test Direction: CCW
Ambient Temperature (°F): 38
Humidity (%): 80
SLW (lbs): 18400
Wind Speed (mpg) & Direction: 5/SW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:05 9:05 50.6 63.1
ART #1 0 4:15 4:15 49.2 60.8
CBD #2 0 9:19 9:19 38.7 60.0
Art #2 0 4:20 4:20 46.3 60.1
CBD #3 0 9:19 9:19 40.1 60.3
Commuter 0 6:03 6:03 48.6 71.9
Total Fuel: 376.20000000000005 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: none

Date: 1995-01-18
Run Number: 3
Personnel: B.L. & R.H.
Test Direction: CW
Ambient Temperature (°F): 38
Humidity (%): 80
SLW (lbs): 18400
Wind Speed (mpg) & Direction: 5/SW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:04 9:04 48.5 60.9
ART #1 0 4:22 4:22 51.4 57.9
CBD #2 0 9:25 9:25 44.0 60.8
Art #2 0 4:21 4:21 51.9 57.2
CBD #3 0 9:27 9:27 44.4 60.4
Commuter 0 6:04 6:04 52.8 67.7
Total Fuel: 364.9 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: none

Date: 1995-01-18
Run Number: 4
Personnel: B.L. & R.H.
Test Direction: CCW
Ambient Temperature (°F): 38
Humidity (%): 80
SLW (lbs): 18400
Wind Speed (mpg) & Direction: 5/SW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:16 9:16 57.7 61.8
ART #1 0 4:25 4:25 55.3 59.9
CBD #2 0 9:22 9:22 47.5 61.1
Art #2 0 4:20 4:20 55.8 57.8
CBD #3 0 9:23 9:23 48.2 59.9
Commuter 0 6:08 6:08 54.3 67.0
Total Fuel: 367.49999999999994 SCF
20 minute idle: 43.6 SCF
No Load Flow Rate at Idle = 1.99 SCFM No Load Flow Rate at Full Throttle = 28.7 SCFM
Heating Value = 1008.1 BTU/LB
Comments: none