CNG-28

CHANCE COACH, INC. Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 1995-03-13
Run Number: 1
Personnel: B.L. & R.H.
Test Direction: CW
Ambient Temperature (°F): 55
Humidity (%): 60
SLW (lbs): 26100
Wind Speed (mpg) & Direction: /Calm
Barometric Pressure (in.Hg): 31
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:58 8:58 80.3 64.8
ART #1 0 4:28 4:28 76.8 58.0
CBD #2 0 9:08 9:08 85.8 63.9
Art #2 0 4:25 4:25 75.9 58.1
CBD #3 0 9:03 9:03 81.2 63.7
Commuter 0 6:03 6:03 84.9 66.0
Total Fuel: 374.5 SCF
20 minute idle: 34.2 SCF
No Load Flow Rate at Idle = 1.9 SCFM No Load Flow Rate at Full Throttle = 21.05 SCFM
Heating Value = 1008.1 BTU/LB
Comments:

Date: 1995-03-13
Run Number: 2
Personnel: B.L. & R.H.
Test Direction: CCW
Ambient Temperature (°F): 63
Humidity (%): 58
SLW (lbs): 26100
Wind Speed (mpg) & Direction: 2/NW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:55 8:55 90.8 68.6
ART #1 0 4:21 4:21 88.7 57.5
CBD #2 0 8:51 8:51 83.7 66.7
Art #2 0 4:27 4:27 75.3 57.0
CBD #3 0 9:10 9:10 86.7 64.3
Commuter 0 6:04 6:04 87.5 63.5
Total Fuel: 377.6 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments:

Date: 1995-03-13
Run Number: 3
Personnel: B.L. & R.H.
Test Direction: CW
Ambient Temperature (°F): 67
Humidity (%): 55
SLW (lbs): 26100
Wind Speed (mpg) & Direction: 2/W
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:59 8:59 89.2 64.3
ART #1 0 4:29 4:29 88.3 56.1
CBD #2 0 9:05 9:05 77.0 63.5
Art #2 0 4:23 4:23 83.3 56.2
CBD #3 0 9:09 9:09 75.4 63.0
Commuter 0 6:05 6:05 83.6 64.8
Total Fuel: 367.90000000000003 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments:

Date: 1995-03-13
Run Number: 4
Personnel: B.L. & R.H.
Test Direction: CCW
Ambient Temperature (°F): 67
Humidity (%): 55
SLW (lbs): 26100
Wind Speed (mpg) & Direction: 2/W
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:03 9:03 87.3 66.8
ART #1 0 4:20 4:20 89.9 56.5
CBD #2 0 9:06 9:06 78.5 65.3
Art #2 0 4:21 4:21 87.1 56.9
CBD #3 0 9:00 9:00 78.3 65.8
Commuter 0 6:00 6:00 87.2 66.1
Total Fuel: 377.4 SCF
20 minute idle: 29.7 SCF
No Load Flow Rate at Idle = 1.6 SCFM No Load Flow Rate at Full Throttle = 22.0 SCFM
Heating Value = 1008.1 BTU/LB
Comments: