Fuel Economy Data (Gaseous Fuels)

Date: 1995-05-03
Run Number: 1
Personnel: B.L., S.C. and R.H.
Test Direction: CCW
Ambient Temperature (°F): 58
Humidity (%): 50
SLW (lbs): 32400
Wind Speed (mpg) & Direction: 2/SE
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:38 9:38 77.8 89.9
ART #1 0 4:44 4:44 81.8 76.9
CBD #2 0 9:37 9:37 78.8 91.0
Art #2 0 4:42 4:42 85.2 77.2
CBD #3 0 9:39 9:39 81.5 89.6
Commuter 0 6:02 6:02 98.7 90.1
Total Fuel: 514.7 SCF
20 minute idle: 48.2 SCF
No Load Flow Rate at Idle = 2.5 SCFM No Load Flow Rate at Full Throttle = 7.7 SCFM
Heating Value = 1008.1 BTU/LB
Comments: None

Date: 1995-05-03
Run Number: 2
Personnel: B.L., S.C. and R.H.
Test Direction: CW
Ambient Temperature (°F): 60
Humidity (%): 50
SLW (lbs): 32400
Wind Speed (mpg) & Direction: 2/se
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:38 9:38 85.3 89.4
ART #1 0 4:43 4:43 90.9 75.1
CBD #2 0 9:43 9:43 88.4 89.5
Art #2 0 4:44 4:44 93.2 74.5
CBD #3 0 9:34 9:34 90.5 89.0
Commuter 0 6:02 6:02 94.5 91.7
Total Fuel: 509.2 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: None

Date: 1995-05-03
Run Number: 3
Personnel: B.L., S.C., and R.H.
Test Direction: CCW
Ambient Temperature (°F): 65
Humidity (%): 48
SLW (lbs): 32400
Wind Speed (mpg) & Direction: 8/n
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:25 9:25 85.6 89.1
ART #1 0 4:35 4:35 89.2 76.2
CBD #2 0 9:30 9:30 86.8 89.3
Art #2 0 4:34 4:34 92.7 75.7
CBD #3 0 9:38 9:38 89.5 89.4
Commuter 0 6:02 6:02 92.5 93.7
Total Fuel: 513.4000000000001 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: None

Date: 1995-05-03
Run Number: 4
Personnel: B.L., S.C., and R.H.
Test Direction: CW
Ambient Temperature (°F): 62
Humidity (%): 48
SLW (lbs): 32400
Wind Speed (mpg) & Direction: 8/nw
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:14 9:14 87.8 88.3
ART #1 0 4:42 4:42 90.1 75.8
CBD #2 0 9:24 9:24 86.4 88.3
Art #2 0 4:40 4:40 92.1 75.0
CBD #3 0 9:32 9:32 88.3 88.9
Commuter 0 6:02 6:02 92.9 93.3
Total Fuel: 509.59999999999997 SCF
20 minute idle: 47.4 SCF
No Load Flow Rate at Idle = 2.4 SCFM No Load Flow Rate at Full Throttle = 7.1 SCFM
Heating Value = 1008.1 BTU/LB
Comments: None