D40 INVERO

NEW FLYER Pdf Download PDF Report

Static Towing Test Data Form

Date: 2002-07-11
Personnel: E.L., M.H., D.L., & K.D.
Temperature: 77

 

Inspect right front tow eye and adjoining structure.
Comments: Verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage or deformation.
Inspect left front tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
Inspect right rear tow eye and adjoining structure.
Comments: Verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Weld broke at approx. 24,900 lbs during left pull.
Inspect left rear tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
General comments of any other structure deformation or failure:
The front 20 degree up, down and right pulls were performed to the full target test load of 33,840 lbs. At approx. 24,900 lbs of force during the 20 degree left pull, the right tow eye weld failed terminated further testing. Rear towing is not recommended.