3600

MOLLY CORPORATION Pdf Download PDF Report

Interior Noise Test Data Form

Test Condition 2: 0 to 35 mph Acceleration Test

Date 1996-02-07
Personnel B.L., S.C. and B.S.
Temperature (°F) 33
Humidity (%) 65
Wind Direction n
Wind Speed (MPH) 3
Barometric Pressure (in.Hg) 30.24
Initial Sound Level Meter Calibration checked by RL
Interior Ambient Noise Level dB(A) 34.0
Exterior Ambient Noise Level dB(A) 43.1
Microphone Height During Testing(in) 45
Measurement Location Measured Sound Level dB(A)
Driver's Seat 85.1
Front Passenger Seats 82.4
Middle Passenger Seats 80.3
Rear Passenger Seats 80.1
Final Sound Level Meter Calibration checked by RL
Comments
All readings taken in the center aisle.