96 DARTD241FL

CHAMPION BUS INC. Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 1996-07-16
Run Number: 1
Personnel: S.C.
Test Direction: CCW
Ambient Temperature (°F): 65
Humidity (%): 60
SLW (lbs): 13825
Wind Speed (mpg) & Direction: 3/W
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:40 8:40 93.3 49.9
ART #1 0 4:06 4:06 93.2 47.3
CBD #2 0 8:47 8:47 97.7 50.8
Art #2 0 3:59 3:59 95.2 49.2
CBD #3 0 8:45 8:45 96.5 50.5
Commuter 0 5:55 5:55 96.2 50.9
Total Fuel: 298.59999999999997 SCF
20 minute idle: 38.3 SCF
No Load Flow Rate at Idle = 2.03 SCFM No Load Flow Rate at Full Throttle = 24.4 SCFM
Heating Value = 1008.1 BTU/LB
Comments: none

Date: 1996-07-16
Run Number: 2
Personnel: S.C.
Test Direction: CW
Ambient Temperature (°F): 67
Humidity (%): 60
SLW (lbs): 13825
Wind Speed (mpg) & Direction: 3/W
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:35 8:35 97.4 51.4
ART #1 0 3:59 3:59 98.4 46.5
CBD #2 0 8:45 8:45 99.1 51.1
Art #2 0 3:51 3:51 100.6 45.7
CBD #3 0 8:55 8:55 99.5 49.8
Commuter 0 6:01 6:01 100.8 50.4
Total Fuel: 294.9 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: none

Date: 1996-07-16
Run Number: 3
Personnel: S.C.
Test Direction: CCW
Ambient Temperature (°F): 75
Humidity (%): 60
SLW (lbs): 13825
Wind Speed (mpg) & Direction: 3/W
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:58 8:58 107.6 50.3
ART #1 0 4:05 4:05 106.1 47.8
CBD #2 0 8:56 8:56 108.8 49.8
Art #2 0 4:06 4:06 105.0 46.9
CBD #3 0 8:52 8:52 102.5 50.0
Commuter 0 5:57 5:57 101.9 52.2
Total Fuel: 297.0 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: none

Date: 1996-07-16
Run Number: 4
Personnel: S.C.
Test Direction: CW
Ambient Temperature (°F): 80
Humidity (%): 60
SLW (lbs): 13825
Wind Speed (mpg) & Direction: 3/W
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:46 8:46 108.3 51.9
ART #1 0 4:01 4:01 108.1 45.3
CBD #2 0 8:50 8:50 108.3 51.2
Art #2 0 4:03 4:03 108.1 45.8
CBD #3 0 8:48 8:48 104.0 49.9
Commuter 0 5:59 5:59 103.9 49.7
Total Fuel: 293.8 SCF
20 minute idle: 32.3 SCF
No Load Flow Rate at Idle = 1.73 SCFM No Load Flow Rate at Full Throttle = 23.56 SCFM
Heating Value = 1008.1 BTU/LB
Comments: none