SENTRY

GOSHEN COACH Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 1997-06-25
Run Number: 1
Personnel: S.C. and R.H.
Test Direction: CCW
Ambient Temperature (°F): 88
Humidity (%): 55
SLW (lbs): 3300
Wind Speed (mpg) & Direction: 12/
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:52 8:52 90.1 59.9
ART #1 0 4:12 4:12 90.7 48.6
CBD #2 0 9:00 9:00 90.0 58.9
Art #2 0 4:13 4:13 90.8 48.8
CBD #3 0 8:58 8:58 91.1 60.7
Commuter 0 5:54 5:54 91.9 61.4
Total Fuel: 338.29999999999995 SCF
20 minute idle: 37.4 SCF
No Load Flow Rate at Idle = 2.15 SCFM No Load Flow Rate at Full Throttle = 20.87 SCFM
Heating Value = 1008.1 BTU/LB
Comments: None

Date: 1997-06-25
Run Number: 2
Personnel: S.C. and R.H.
Test Direction: CW
Ambient Temperature (°F): 88
Humidity (%): 55
SLW (lbs): 3300
Wind Speed (mpg) & Direction: 12/w
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:56 8:56 97.5 60.2
ART #1 0 4:09 4:09 99.0 46.3
CBD #2 0 9:00 9:00 98.6 59.5
Art #2 0 4:10 4:10 99.9 47.0
CBD #3 0 8:56 8:56 98.4 60.1
Commuter 0 5:57 5:57 100.1 62.5
Total Fuel: 335.6 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: None

Date: 1997-06-25
Run Number: 3
Personnel: S.C. and R.H.
Test Direction: CCW
Ambient Temperature (°F): 88
Humidity (%): 55
SLW (lbs): 3300
Wind Speed (mpg) & Direction: 12/w
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:45 8:45 97.2 58.5
ART #1 0 4:08 4:08 98.9 47.9
CBD #2 0 8:51 8:51 99.3 59.8
Art #2 0 4:13 4:13 102.0 47.6
CBD #3 0 8:51 8:51 101.2 58.5
Commuter 0 5:55 5:55 103.2 62.1
Total Fuel: 334.4 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: None

Date: 1997-06-25
Run Number: 4
Personnel: S.C. and R.H.
Test Direction: CW
Ambient Temperature (°F): 88
Humidity (%): 55
SLW (lbs): 3300
Wind Speed (mpg) & Direction: 12/w
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:56 8:56 104.0 59.8
ART #1 0 4:09 4:09 105.3 45.4
CBD #2 0 9:03 9:03 104.0 60.0
Art #2 0 4:10 4:10 106.2 46.1
CBD #3 0 9:00 9:00 104.8 60.2
Commuter 0 5:50 5:50 106.9 63.1
Total Fuel: 334.6 SCF
20 minute idle: 39.0 SCF
No Load Flow Rate at Idle = 2.09 SCFM No Load Flow Rate at Full Throttle = 20.18 SCFM
Heating Value = 1008.1 BTU/LB
Comments: None