40/102TB M11

GILLIG CORPORATION Pdf Download PDF Report

Structural Shakedown Data Form

Loading Sequence: 1

Date: 1997-06-23 Temperature: 78
Personnel: S.C., J.P., and G.F. Test Load (lbs): 26250
Reference Point No. A (in) Original Height B (in) Loaded Height B-A (in) Loaded Deflection C (in) Unloaded Height C-A (in) Permanent Deflection
1 0.000 0.062 0.062 -0.003 -0.003
2 0.000 0.108 0.108 14.000 14.000
3 0.000 0.138 0.138 0.017 0.017
4 0.000 0.128 0.128 0.017 0.017
5 0.000 0.096 0.096 0.017 0.017
6 0.000 0.069 0.069 0.019 0.019
7 0.000 0.055 0.055 0.013 0.013
8 0.000 0.081 0.081 0.011 0.011
9 0.000 0.153 0.153 0.018 0.018
10 0.000 0.212 0.212 0.021 0.021
11 0.000 0.159 0.159 0.016 0.016
12 0.000 0.079 0.079 0.003 0.003

Loading Sequence: 1

Date: 1997-06-23 Temperature: 78
Personnel: S.C., J.P., and G.F. Test Load (lbs): 26250
Reference Point No. A (in) Original Height B (in) Loaded Height B-A (in) Loaded Deflection C (in) Unloaded Height C-A (in) Permanent Deflection
1 -0.003 0.064 0.067 -0.003 0.000
2 0.014 0.118 0.104 0.015 0.001
3 0.017 0.142 0.125 0.018 0.001
4 0.017 0.130 0.113 0.019 0.002
5 0.017 0.099 0.082 0.018 0.001
6 0.019 0.070 0.051 0.022 0.003
7 0.013 0.057 0.044 0.016 0.003
8 0.011 0.085 0.074 0.013 0.002
9 0.018 0.159 0.141 0.019 0.001
10 0.021 0.225 0.204 0.022 0.001
11 0.016 0.162 0.146 0.016 0.000
12 0.003 0.079 0.076 0.003 0.000