Cassic 28" Raised Roof

METROTRANS CORPORATION Pdf Download PDF Report

Interior Noise Test Data Form

Test Condition 2: 0 to 35 mph Acceleration Test

Date 1998-07-29
Personnel B.L., S.C., and R.H.
Temperature (°F) 78
Humidity (%) 65
Wind Direction SW
Wind Speed (MPH) 6
Barometric Pressure (in.Hg) 30.0
Initial Sound Level Meter Calibration checked by B.L..
Interior Ambient Noise Level dB(A) 34.0
Exterior Ambient Noise Level dB(A) 45.5
Microphone Height During Testing(in) 45
Measurement Location Measured Sound Level dB(A)
Driver's Seat 74.8
Front Passenger Seats 72.6
Middle Passenger Seats 72.3
Rear Passenger Seats 70.3
Final Sound Level Meter Calibration checked by B.L.
Comments
All readings taken in the center aisle.