Sentinel

GOSHEN COACH Pdf Download PDF Report

Static Towing Test Data Form

Date: 1999-06-14
Personnel: S.C., E.L., D.L. and M.H.
Temperature: 75

 

Inspect right front tow eye and adjoining structure.
Comments: Torques verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage or deformation.
Inspect left front tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
Inspect right rear tow eye and adjoining structure.
Comments: Torques verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage or deformation.
Inspect left rear tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
General comments of any other structure deformation or failure:
The 20 degree up and 20 degree down pulls were completed to the full target test weight of 16,548 lbs. During the 20 degree left pull, deformation of the attaching plate from the main frame to the toe eye was observed terminating further testing.