Universal
GLAVAL BUS
|
Air Conditioning - OFF | Yes |
Ventilation Fans - ON HIGH | Yes |
Heater pump motor - OFF | Yes |
Defroster - OFF | Yes |
Exterior and Interior Lights - ON | Yes |
Windows and Doors - CLOSED | Yes |
Acceleration, Gradeability, Top Speed
Counter Clockwise Recorded Interval Times | |||
---|---|---|---|
Speed | Run 1 | Run 2 | Run 3 |
10 mph | 2.92 | 2.64 | 2.69 |
20 mph | 5.48 | 5.42 | 5.04 |
30 mph | 8.32 | 8.36 | 8.19 |
40 mph | 12.85 | 12.42 | 12.44 |
Top Test
Speed (50 mph) |
19.3 | 19.26 | 19.03 |
Clockwise Recorded Interval Times | |||
Speed | Run 1 | Run 2 | Run 3 |
10 mph | 2.86 | 2.85 | 2.7 |
20 mph | 5.33 | 5.07 | 4.79 |
30 mph | 8.17 | 8.14 | 7.82 |
40 mph | 11.92 | 11.89 | 11.76 |
Top Test
Speed (50 mph) |
18.05 | 18.04 | 17.64 |
General
Check-In
Back to Bus List
- Summary
- Weight
- Clearances
- Body Details
- Engine
- Transmission
- Suspension
- Wheels & Tires
- Brakes
- HVAC
- Steering
- Capacities
- Misc.
- Components
- Spare Parts
- Integrity Summary
- Shakedown
- Distortion Summary
- Distortion Test
- Static Towing Summary
- Static Towing Test
- Dynamic Towing Summary
- Dynamic Towing Test
- Jacking Summary
- Jacking Test
- Hoisting Summary
- Hoisting Test
- Durability Summary
- Durability Mileage
- Unscheduled Maintenance
- Interior Summary
- Stationary Test
- Acceleration Test
- Vibration Test
- Exterior Summary
- Constant Acceleration
- Standstill Acceleration
- Stationary
Back to Bus List