ECOMARK SHUTTLE BUS

TRANSPORATION TECHNIQUES LLC Pdf Download PDF Report

Static Towing Test Data Form

Date: 1999-11-18
Personnel: B.L., S.C., E.L., J.P., & G.F.
Temperature:

 

Inspect right front tow eye and adjoining structure.
Comments: Welds inspected.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage or deformation.
Inspect left front tow eye and adjoining structure.
Comments: Welds inspected.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage or deformation.
Inspect right rear tow eye and adjoining structure.
Comments: Welds inspected.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage or deformation.
Inspect left rear tow eye and adjoining structure.
Comments: The right side tow eye has a 2'' crack.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: The right side tow eye has a 2'' crack.
General comments of any other structure deformation or failure:
All four front pulls were completed to the full target test weight of 30,360 lbs. with no damage or deformation observed. During the 20 degree rear down pull, the right rear tow eye insert experienced a 2'' crack terminating further testing of rear tow eyes.