Passport

ELDORADO NATIONAL Pdf Download PDF Report

Static Towing Test Data Form

Date:
Personnel: T.S., S.C., E.L.& E.D.
Temperature: 22

 

Inspect right front tow eye and adjoining structure.
Comments: No damage or deformation observed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Torgues and welds verified.
Inspect left front tow eye and adjoining structure.
Comments: No damage or deformation observed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Torgues and welds verified.
Inspect right rear tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
Inspect left rear tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
General comments of any other structure deformation or failure:
<p>All four front pulls were completed to the full target test load of 21, 910 lbs (1.2 x 18,300 lbs) with no damage or deformation observed.&nbsp; The manufacturer does not recommend towing from the rear, therefore, a rear test was not performed.</p>