2009 GAS HYBRID

ARBOC MOBILITY, LLC Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2009-09-02
Run Number: 4
Personnel: T.W. & S.C.
Test Direction: CW
Ambient Temperature (°F): 68
Humidity (%): 66
SLW (lbs): 12850
Wind Speed (mpg) & Direction: /
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:47 8:47 25.8 0.276
ART #1 0 4:12 4:12 28.6 0.2634
CBD #2 0 8:50 8:50 29.1 0.2747
Art #2 0 4:11 4:11 29.9 0.2625
CBD #3 0 8:52 8:52 29.8 0.2745
Commuter 0 6:01 6:01 30.1 0.3516
Total Fuel: 1.7027 SCF
20 minute idle: 0.1834 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 20025.0 BTU/LB
Comments: None noted.

Date: 2009-09-01
Run Number: 1
Personnel: T.W., T.S. & S.C.
Test Direction: CCW
Ambient Temperature (°F): 63
Humidity (%): 59
SLW (lbs): 12850
Wind Speed (mpg) & Direction: 5/SW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:46 8:46 25.6 0.2915
ART #1 0 4:03 4:03 27.2 0.2834
CBD #2 0 8:46 8:46 29.2 0.285
Art #2 0 4:13 4:13 29.3 0.2775
CBD #3 0 8:44 8:44 29.2 0.2878
Commuter 0 5:54 5:54 29.4 0.3622
Total Fuel: 1.7874 SCF
20 minute idle: 0.1872 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 20025.0 BTU/LB
Comments: None noted.

Date: 2009-09-01
Run Number: 2
Personnel: T.W., T.S. & S.C.
Test Direction: CW
Ambient Temperature (°F): 65
Humidity (%): 59
SLW (lbs): 12
Wind Speed (mpg) & Direction: 5/NW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:44 8:44 29.2 0.2864
ART #1 0 4:02 4:02 28.9 0.2726
CBD #2 0 8:47 8:47 28.6 0.2836
Art #2 0 4:08 4:08 28.7 0.2699
CBD #3 0 8:45 8:45 28.4 0.277
Commuter 0 5:57 5:57 29.3 0.3568
Total Fuel: 1.7463 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 20025.0 BTU/LB
Comments: None noted.

Date: 2009-09-02
Run Number: 3
Personnel: T.W. & S.C.
Test Direction: CCW
Ambient Temperature (°F): 62
Humidity (%): 72
SLW (lbs): 12850
Wind Speed (mpg) & Direction: 0/
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:45 8:45 24.6 0.2749
ART #1 0 4:06 4:06 26.4 0.2723
CBD #2 0 8:48 8:48 26.2 0.2777
Art #2 0 4:11 4:11 26.2 0.2745
CBD #3 0 8:51 8:51 25.9 0.2809
Commuter 0 5:55 5:55 25.8 0.3551
Total Fuel: 1.7353999999999998 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 20025.0 BTU/LB