Static Towing Test Data Form
Date:
|
2008-08-27
|
Personnel:
|
T.S., S.C. & E.D.
|
Temperature:
|
78
|
Inspect right front tow eye and adjoining structure. |
Comments:
No damage or deformation observed.
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
Welds verified.
|
Inspect left front tow eye and adjoining structure. |
Comments:
No damage or deformation observed.
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
Welds verified.
|
Inspect right rear tow eye and adjoining structure. |
Comments:
N/A
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
N/A
|
Inspect left rear tow eye and adjoining structure. |
Comments:
N/A
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
N/A
|
General comments of any other structure deformation or failure: |
<p>All four front pulls were completed to the full target test load of 49,572 lbs. (1.2x41,310 lbs CW). No damage or deformation was observed. The manufacturer does not recommend rear towing, therefore, a rear test was not performed.</p> |
|
|