Azure Dynamics Inc. Balance Hybride E-450 With Senator Body

AZURE DYNAMICS INC. Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2008-09-11
Run Number: 1
Personnel: B.S., T.S. & S.C.
Test Direction: CCW
Ambient Temperature (°F): 70
Humidity (%): 63
SLW (lbs): 13900
Wind Speed (mpg) & Direction: 5/SE
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:27 8:27 43.0 0.308
ART #1 0 3:59 3:59 62.5 0.242
CBD #2 0 8:24 8:24 59.5 0.275
Art #2 0 4:06 4:06 33.6 0.259
CBD #3 0 8:27 8:27 22.1 0.277
Commuter 0 5:56 5:56 21.6 0.315
Total Fuel: 1.6760000000000002 SCF
20 minute idle: .118 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 20025.0 BTU/LB
Comments:

Date: 2008-09-11
Run Number: 2
Personnel: B.S., T.S. & S.C.
Test Direction: CW
Ambient Temperature (°F): 70
Humidity (%): 63
SLW (lbs): 13900
Wind Speed (mpg) & Direction: 5/SE
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:30 8:30 22.2 0.294
ART #1 0 4:01 4:01 22.0 0.234
CBD #2 0 8:28 8:28 21.5 0.288
Art #2 0 3:58 3:38 21.5 0.25
CBD #3 0 8:31 8:31 21.0 0.296
Commuter 0 6:03 6:03 21.5 0.325
Total Fuel: 1.687 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 20025.0 BTU/LB
Comments:

Date: 2008-09-11
Run Number: 3
Personnel: B.S., T.S. & S.C.
Test Direction: CCW
Ambient Temperature (°F): 68
Humidity (%): 69
SLW (lbs): 13900
Wind Speed (mpg) & Direction: 5/SE
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:14 8:14 20.5 0.314
ART #1 0 4:02 4:02 20.0 0.25
CBD #2 0 8:26 8:26 21.0 0.243
Art #2 0 3:58 3:58 21.3 0.259
CBD #3 0 8:32 8:32 21.7 0.254
Commuter 0 6:03 6:03 21.2 0.345
Total Fuel: 1.665 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 20025.0 BTU/LB
Comments:

Date: 2008-09-11
Run Number: 4
Personnel: B.S., T.S. & S.C.
Test Direction: CW
Ambient Temperature (°F): 68
Humidity (%): 69
SLW (lbs): 13900
Wind Speed (mpg) & Direction: 5/SE
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:32 8:32 21.2 0.3
ART #1 0 4:04 4:04 21.4 0.267
CBD #2 0 8:27 8:27 21.4 0.286
Art #2 0 4:06 4:06 21.5 0.258
CBD #3 0 8:26 8:26 21.4 0.276
Commuter 0 6:06 6:06 21.7 0.353
Total Fuel: 1.74 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 20025 BTU/LB
Comments: