SLC-938

Stallion Bus Industries, LLC Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2008-11-05
Run Number: 1
Personnel: B.S., T.S. & S.C.
Test Direction: CCW
Ambient Temperature (°F): 56
Humidity (%): 72
SLW (lbs): 31820
Wind Speed (mpg) & Direction: 5/SE
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:41 8:41 19.6 0.549
ART #1 0 4:11 4:11 19.6 0.477
CBD #2 0 8:42 8:42 19.7 0.613
Art #2 0 4:14 4:14 19.8 0.489
CBD #3 0 8:39 8:39 19.9 0.626
Commuter 0 6:00 6:00 19.7 0.497
Total Fuel: 3.251 SCF
20 minute idle: .203 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631 BTU/LB
Comments:

Date: 2008-11-05
Run Number: 2
Personnel: B.S., T.S. & S.C.
Test Direction: CW
Ambient Temperature (°F): 59
Humidity (%): 72
SLW (lbs): 31820
Wind Speed (mpg) & Direction: 5/NE
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:50 8:50 19.7 0.596
ART #1 0 4:19 4:19 20.3 0.473
CBD #2 0 8:42 8:42 21.2 0.618
Art #2 0 4:18 4:18 21.2 0.48
CBD #3 0 8:51 8:51 21.7 0.626
Commuter 0 6:10 6:10 21.8 0.49
Total Fuel: 3.2829999999999995 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631.0 BTU/LB
Comments:

Date: 2008-11-05
Run Number: 3
Personnel: B.S., T.S. & S.C.
Test Direction: CCW
Ambient Temperature (°F): 64
Humidity (%): 64
SLW (lbs): 31820
Wind Speed (mpg) & Direction: 7/NE
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:32 8:32 21.6 0.605
ART #1 0 4:10 4:10 21.9 0.472
CBD #2 0 8:38 8:38 21.8 0.61
Art #2 0 4:08 4:08 21.9 0.485
CBD #3 0 8:44 8:44 21.9 0.556
Commuter 0 6:02 6:02 22.2 0.508
Total Fuel: 3.2359999999999998 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631 BTU/LB
Comments:

Date: 2008-11-05
Run Number: 4
Personnel: B.S., T.S. & S.C.
Test Direction: CW
Ambient Temperature (°F): 66
Humidity (%): 64
SLW (lbs): 31820
Wind Speed (mpg) & Direction: 7/NE
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:54 8:54 22.2 0.603
ART #1 0 4:15 4:15 21.8 0.465
CBD #2 0 8:50 8:50 22.6 0.61
Art #2 0 4:22 4:22 22.7 0.472
CBD #3 0 8:48 8:48 22.5 0.612
Commuter 0 6:00 6:00 22.6 0.506
Total Fuel: 3.268 SCF
20 minute idle: .238 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631.0 BTU/LB
Comments: