Static Towing Test Data Form
Date:
|
2009-01-09
|
Personnel:
|
T.S., E.L., E.D. & P.D.
|
Temperature:
|
30
|
Inspect right front tow eye and adjoining structure. |
Comments:
Center receiver and adjacent structure bent upward during the 20° up pull.
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
Center receiver and adjacent structure bent upward during the 20° up pull.
|
Inspect left front tow eye and adjoining structure. |
Comments:
Center receiver and adjacent structure bent upward during the 20° up pull.
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
Center receiver and adjacent structure bent upward during the 20° up pull.
|
Inspect right rear tow eye and adjoining structure. |
Comments:
N/A
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
N/A
|
Inspect left rear tow eye and adjoining structure. |
Comments:
N/A
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
N/A
|
General comments of any other structure deformation or failure: |
<p>The 20° up pull was completed to the full target test load of 31,224 lbs (1.2x26,020 lbs). Inspection found the center receiver and adjacent structure deformed upward during the 20° up pull.</p> |
|
|