DODGE GRAND CARAVAN

ECLIPSE SPECIALTY VEHICLES Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2009-02-02
Run Number: 1
Personnel: C.S., T.S. & S.C.
Test Direction: CCW
Ambient Temperature (°F): 35
Humidity (%): 76
SLW (lbs): 5860
Wind Speed (mpg) & Direction: 2/SW
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:31 9:31 6.5 0.182
ART #1 0 4:01 4:01 5.8 0.1514
CBD #2 0 9:22 9:22 6.1 0.1766
Art #2 0 4:07 4:07 4.2 0.1467
CBD #3 0 8:53 8:53 4.8 0.1764
Commuter 0 6:08 6:08 3.6 0.1771
Total Fuel: 1.0102 SCF
20 minute idle: .1510 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 20025 BTU/LB
Comments: CBD #2 was re-run due to loss of power to the Daytron Unit.

Date: 2009-02-02
Run Number: 2
Personnel: C.S., T.S. & S.C.
Test Direction: CW
Ambient Temperature (°F): 38
Humidity (%): 61
SLW (lbs): 5860
Wind Speed (mpg) & Direction: 6/WSW
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:09 9:9 4.5 0.1826
ART #1 0 4:06 4:06 4.0 0.1506
CBD #2 0 9:08 9:08 3.7 0.181
Art #2 0 4:07 4:07 3.1 0.1476
CBD #3 0 9:25 9:25 2.8 0.1766
Commuter 0 6:06 6:06 2.2 0.1784
Total Fuel: 1.0168 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 20025 BTU/LB
Comments:

Date: 2009-02-02
Run Number: 3
Personnel: C.S., T.S. & S.C.
Test Direction: CCW
Ambient Temperature (°F): 36
Humidity (%): 69
SLW (lbs): 5860
Wind Speed (mpg) & Direction: 3/WSW
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:22 9:22 2.2 0.1878
ART #1 0 4:05 4:05 2.2 0.1507
CBD #2 0 9:23 9:23 2.1 0.1796
Art #2 0 4:02 4:02 2.3 0.1542
CBD #3 0 9:23 9:23 2.3 0.1802
Commuter 0 5:57 5:57 2.2 0.1796
Total Fuel: 1.0321 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 20025 BTU/LB
Comments:

Date: 2009-02-02
Run Number: 4
Personnel: C.S., T.S. & S.C.
Test Direction: CW
Ambient Temperature (°F): 38
Humidity (%): 59
SLW (lbs): 5860
Wind Speed (mpg) & Direction: 7/NW
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:19 9:19 2.5 0.1764
ART #1 0 4:09 4:09 2.3 0.1466
CBD #2 0 9:03 9:03 2.2 0.179
Art #2 0 4:09 4:09 2.3 0.1782
CBD #3 0 9:12 9:12 2.3 0.1782
Commuter 0 6:00 6:00 1.9 0.1841
Total Fuel: 1.0425 SCF
20 minute idle: .1480 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 20025.0 BTU/LB
Comments: