Odyssey XLT

TURTLE TOP Pdf Download PDF Report

Static Towing Test Data Form

Date: 2010-03-08
Personnel: T.S., B.L., E.L. & E.D.
Temperature: 50

 

Inspect right front tow eye and adjoining structure.
Comments: No damage or deformation observed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Welds inspected.
Inspect left front tow eye and adjoining structure.
Comments: No damage or deformation observed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Welds inspected.
Inspect right rear tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
Inspect left rear tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
General comments of any other structure deformation or failure:
<p>All four front pulls were completed to the full target test load of 24,036 lbs. (1.2 x 20,030 lbs CW) No damage or deformation was observed.&nbsp; Manufacturer recommends no towing from the rear.</p>