Ford F550

GOSHEN COACH Pdf Download PDF Report

Static Towing Test Data Form

Date: 2010-08-05
Personnel: T.S., E.L., B.L., E.D. &B.L.
Temperature: 82

 

Inspect right front tow eye and adjoining structure.
Comments: No damage or deformation observed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Torques verified.
Inspect left front tow eye and adjoining structure.
Comments: No damage or deformation observed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Torques verified.
Inspect right rear tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
Inspect left rear tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
General comments of any other structure deformation or failure:
<p>All four front pulls were completed to the full test load of 16,140 lbs (1.2x12,450 lbs CW) with no damage or deformation observed.</p>