LFS - 60'

NOVA BUS Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2010-03-17
Run Number: 1
Personnel: C.S., T.S. & S.C.
Test Direction: CCW
Ambient Temperature (°F): 57
Humidity (%): 27
SLW (lbs): 47480
Wind Speed (mpg) & Direction: /
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:15 9:15 19.2 0.628
ART #1 0 4:29 4:29 18.6 0.571
CBD #2 0 9:01 9:01 19.4 0.639
Art #2 0 4:25 4:25 18.2 0.562
CBD #3 0 8:58 8:58 18.4 0.634
Commuter 0 6:01 6:01 18.6 0.636
Total Fuel: 3.67 SCF
20 minute idle: .302 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631.0 BTU/LB
Comments:

Date: 2010-03-17
Run Number: 2
Personnel: C.S., T.S. & S.C.
Test Direction: CW
Ambient Temperature (°F): 60
Humidity (%): 27
SLW (lbs): 47480
Wind Speed (mpg) & Direction: /
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:07 9:07 18.0 0.628
ART #1 0 4:28 4:28 18.6 0.561
CBD #2 0 9:05 9:05 19.4 0.645
Art #2 0 4:28 9:28 19.2 0.572
CBD #3 0 9:12 9:12 19.6 0.631
Commuter 0 6:00 6:00 19.8 0.647
Total Fuel: 3.684 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631.0 BTU/LB
Comments:

Date: 2010-03-18
Run Number: 3
Personnel: C.S., T.S. & S.C.
Test Direction: CCW
Ambient Temperature (°F): 42
Humidity (%): 59
SLW (lbs): 47480
Wind Speed (mpg) & Direction: 3/S
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:32 9:32 15.6 0.63
ART #1 0 4:28 4:28 15.8 0.561
CBD #2 0 9:31 9:31 16.2 0.639
Art #2 0 4:27 4:27 16.2 0.567
CBD #3 0 9:23 9:23 16.8 0.636
Commuter 0 6:07 6:07 16.2 0.616
Total Fuel: 3.6490000000000005 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631.0 BTU/LB
Comments:

Date: 2010-03-18
Run Number: 4
Personnel: C.S., T.S. & S.C.
Test Direction: CW
Ambient Temperature (°F): 44
Humidity (%): 59
SLW (lbs): 47480
Wind Speed (mpg) & Direction: 3/S
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:27 9:27 17.6 0.626
ART #1 0 4:25 4:25 17.2 0.577
CBD #2 0 9:25 9:25 17.5 0.634
Art #2 0 4:28 4:28 17.8 0.551
CBD #3 0 9:09 9:09 18.2 0.627
Commuter 0 6:03 6:03 18.2 0.695
Total Fuel: 3.7099999999999995 SCF
20 minute idle: .357 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631.0 BTU/LB
Comments: