Model Universal CNG

GLAVAL BUS/DIV. OF FOREST RIVER Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2010-09-15
Run Number: 4
Personnel: B.G., T.S. & E.L.
Test Direction: CW
Ambient Temperature (°F): 59
Humidity (%): 63
SLW (lbs): 13670
Wind Speed (mpg) & Direction: /
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:23 8:23 76.0 48.0
ART #1 0 3:48 3:48 72.0 47.0
CBD #2 0 8:14 8:14 78.0 50.0
Art #2 0 3:49 3:49 74.0 47.0
CBD #3 0 8:16 8:16 80.0 49.0
Commuter 0 5:54 5:54 79.0 52.0
Total Fuel: 293.0 SCF
20 minute idle: 54 SCF
No Load Flow Rate at Idle = 2.7 SCFM No Load Flow Rate at Full Throttle = 8.4 SCFM
Heating Value = 1008.1 BTU/LB
Comments:

Date: 2010-09-10
Run Number: 1
Personnel: B.L., S.C., E.D. & B.G.
Test Direction: CCW
Ambient Temperature (°F): 35
Humidity (%): 50
SLW (lbs): 13670
Wind Speed (mpg) & Direction: 7/NNW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:23 8:23 76.0 55.0
ART #1 0 3:53 3:53 70.0 56.0
CBD #2 0 8:19 8:19 67.0 54.0
Art #2 0 3:50 3:50 65.0 51.0
CBD #3 0 8:20 8:20 70.0 50.0
Commuter 0 5:52 5:52 71.0 54.0
Total Fuel: 320.0 SCF
20 minute idle: 55 SCF
No Load Flow Rate at Idle = 2.8 SCFM No Load Flow Rate at Full Throttle = 9.6 SCFM
Heating Value = 1008.1 BTU/LB
Comments:

Date: 2010-09-14
Run Number: 2
Personnel: B.L., S.C., E.D. & B.G.
Test Direction: CW
Ambient Temperature (°F): 67
Humidity (%): 50
SLW (lbs): 16670
Wind Speed (mpg) & Direction: 7/NNW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:20 8:20 73.0 50.0
ART #1 0 3:50 3:50 67.0 53.0
CBD #2 0 8:15 8:15 70.0 49.0
Art #2 0 3:55 3:55 71.0 50.0
CBD #3 0 8:10 8:10 74.0 50.0
Commuter 0 5:54 5:54 74.0 53.0
Total Fuel: 305.0 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments:

Date: 2010-09-15
Run Number: 3
Personnel: B.G., T.S. & E.L.
Test Direction: CCW
Ambient Temperature (°F): 59
Humidity (%): 63
SLW (lbs): 13670
Wind Speed (mpg) & Direction: /
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:21 8:21 80.0 51.0
ART #1 0 3:48 3:48 73.0 50.0
CBD #2 0 8:19 8:19 76.0 49.0
Art #2 0 3:47 3:47 71.0 48.0
CBD #3 0 8:12 8:12 77.0 50.0
Commuter 0 5:51 5:51 74.0 55.0
Total Fuel: 303.0 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: