2011 Vision Toyota Sienna

VIEW POINT MOBILITY Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2011-03-03
Run Number: 1
Personnel: T.W., T.S. & S.C.
Test Direction: CCW
Ambient Temperature (°F): 32
Humidity (%): 35
SLW (lbs): 5750
Wind Speed (mpg) & Direction: /
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:36 8:36 -15.4 0.1366
ART #1 0 3:58 3:58 -18.1 0.1194
CBD #2 0 8:39 8:39 -11.8 0.1367
Art #2 0 3:59 3:59 -3.1 0.1207
CBD #3 0 8:30 8:30 -2.8 0.1369
Commuter 0 5:55 5:55 -1.6 0.1512
Total Fuel: 0.8015 SCF
20 minute idle: .0933 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 20025.0 BTU/LB
Comments:

Date: 2011-03-03
Run Number: 2
Personnel: T.W., T.S. & S.C.
Test Direction: CW
Ambient Temperature (°F): 32
Humidity (%): 35
SLW (lbs): 5750
Wind Speed (mpg) & Direction: 2/NNW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8.44 8:44 -1.6 0.137
ART #1 0 4:02 4:02 2.3 0.1179
CBD #2 0 8:41 8:41 5.4 0.1367
Art #2 0 4:02 4:02 7.0 0.1184
CBD #3 0 8:42 8:42 7.6 0.1363
Commuter 0 5:58 5:58 8.8 0.1507
Total Fuel: 0.7969999999999999 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 20025.0 BTU/LB
Comments:

Date: 2011-03-03
Run Number: 3
Personnel: T.W., T.S. & S.C.
Test Direction: CCW
Ambient Temperature (°F): 36
Humidity (%): 35
SLW (lbs): 5750
Wind Speed (mpg) & Direction: 2/NNW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:40 8:40 8.7 0.1387
ART #1 0 3:56 3:56 8.4 0.1222
CBD #2 0 8:42 8:42 7.9 0.1367
Art #2 0 4:04 4:04 5.7 0.1156
CBD #3 0 8:38 8:38 4.4 0.1347
Commuter 0 5:53 5:53 2.3 0.1508
Total Fuel: 0.7987 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 20025.0 BTU/LB
Comments:

Date: 2011-03-03
Run Number: 4
Personnel: T.W., T.S. & S.C.
Test Direction: CW
Ambient Temperature (°F): 38
Humidity (%): 35
SLW (lbs): 5750
Wind Speed (mpg) & Direction: /
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:33 8:33 3.6 0.1344
ART #1 0 4:06 4:06 6.8 0.1173
CBD #2 0 8:37 8:37 6.0 0.1369
Art #2 0 4:05 4:05 6.3 0.1152
CBD #3 0 8:39 8:39 7.0 0.1355
Commuter 0 5:57 5:57 6.9 0.1475
Total Fuel: 0.7867999999999999 SCF
20 minute idle: .0925 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 20025.0 BTU/LB
Comments: