Static Towing Test Data Form

Date: 2011-05-05
Personnel: T.S., P.D., G.F., J.P. & S.C.
Temperature: 65

 

Inspect right front tow eye and adjoining structure.
Comments: No damage or deformation observed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: All torques verified.
Inspect left front tow eye and adjoining structure.
Comments: No damage or deformation observed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: All torques verified.
Inspect right rear tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
Inspect left rear tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
General comments of any other structure deformation or failure:
<p>All four front pulls were completed to the full target test load of 35,088 lbs. (1.2x29,240 lbs CW) with no damage or deformation observed.&nbsp; No rear test was performed at manufacturer's request.</p>