ODYSSEY LX
INDEPENDENT PROTECTION COMPANY, INC. DBA TURTLE TOP
|
Date | : | 2011-05-09 | |||
Personnel | : | T.W., T.S. & S.C. | |||
Temperature (°F) | : | 60 | Humidity (%) | : | 43 |
Wind Speed (mph) | : | 10 | Wind Direction | : | NNE |
Barometric Pressure (in.Hg) | : | 30.07 | |||
Verify that microphone height is 4 feet, wind speed is less than 12 mpg and ambient temperature is between 30 F and 90 F: true checked by S.C. | |||||
Initial Sound Level Meter Calibration: true checked by S.C. | |||||
Exterior Ambient Noise Level dB(A): 41.5 |
Accelerating from Constant Speed
Curb (Right) Side |
Accelerating from Constant Speed
Street (Left) Side |
||
---|---|---|---|
Run # | Measured Noise Level dB(A) | Run # | Measured Noise Level dB(A) |
1 | 68.1 | 1 | 70.3 |
2 | 67.7 | 2 | 72.6 |
3 | 68.4 | 3 | 72.2 |
4 | 68.9 | 4 | 70.6 |
5 | 68.4 | 5 | 70.1 |
Average of two highest actual noise levels = 68.7 dB(A) | Average of two highest actual noise levels = 72.4 dB(A) |
Final Sound Level Meter Calibration Check: true checked by S.C. |
Comments: |
General
Check-In
Back to Bus List
- Summary
- Weight
- Clearances
- Body Details
- Engine
- Transmission
- Suspension
- Wheels & Tires
- Brakes
- HVAC
- Steering
- Capacities
- Misc.
- Components
- Spare Parts
- Integrity Summary
- Shakedown
- Distortion Summary
- Distortion Test
- Static Towing Summary
- Static Towing Test
- Dynamic Towing Summary
- Dynamic Towing Test
- Jacking Summary
- Jacking Test
- Hoisting Summary
- Hoisting Test
- Durability Summary
- Durability Mileage
- Unscheduled Maintenance
- Interior Summary
- Stationary Test
- Acceleration Test
- Vibration Test
- Exterior Summary
- Constant Acceleration
- Standstill Acceleration
- Stationary
Back to Bus List