XDE40

NEW FLYER Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2011-07-07
Run Number: 3
Personnel: M.R., T.S. & S.C.
Test Direction: CCW
Ambient Temperature (°F): 77
Humidity (%): 78
SLW (lbs): 34000
Wind Speed (mpg) & Direction: /
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:38 3:38 29.9 0.302
ART #1 0 4:01 4:01 29.8 0.337
CBD #2 0 8:20 8:20 30.5 0.33
Art #2 0 3:57 3:57 30.1 0.339
CBD #3 0 8:20 8:20 30.7 0.333
Commuter 0 5:56 5:56 30.2 0.458
Total Fuel: 2.099 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631.0 BTU/LB
Comments: Start SOC: 39.75% End SOC: 39.4%

Date: 2011-07-19
Run Number: 4
Personnel: M.R., T.S. & S.C.
Test Direction: CW
Ambient Temperature (°F): 79
Humidity (%): 78
SLW (lbs): 34000
Wind Speed (mpg) & Direction: /
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:23 8:23 30.8 0.321
ART #1 0 4:04 4:04 30.8 0.329
CBD #2 0 8:25 8:25 31.0 0.317
Art #2 0 4:02 4:02 31.0 0.323
CBD #3 0 8:24 8:24 31.4 0.319
Commuter 0 5:58 5:58 30.7 0.459
Total Fuel: 2.068 SCF
20 minute idle: .214 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631.0 BTU/LB
Comments: Start SOC: 39.5% End SOC: 39.9%

Date: 2011-07-18
Run Number: 1
Personnel: M.R., T.S. & E.D.
Test Direction: CCW
Ambient Temperature (°F): 81
Humidity (%): 65
SLW (lbs): 34000
Wind Speed (mpg) & Direction: 7/W
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:23 8:23 38.7 0.333
ART #1 0 3:55 3:55 37.5 0.355
CBD #2 0 8:06 8:06 38.1 0.317
Art #2 0 4:04 4:04 38.3 0.375
CBD #3 0 8:17 8:17 38.5 0.327
Commuter 0 5:55 5:55 36.8 0.467
Total Fuel: 2.174 SCF
20 minute idle: .200 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631.0 BTU/LB
Comments: Start SOC: 39.9% End SOC: 39.5%

Date: 2011-07-18
Run Number: 2
Personnel: M.R., T.S. & E.D.
Test Direction: CW
Ambient Temperature (°F): 84
Humidity (%): 51
SLW (lbs): 34000
Wind Speed (mpg) & Direction: 12/WSW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8;34 8:34 39.5 0.31
ART #1 0 3:59 3:59 39.5 0.338
CBD #2 0 8;26 8:26 40.3 0.314
Art #2 0 4:00 4:00 40.5 0.366
CBD #3 0 8:22 8:22 41.5 0.344
Commuter 0 5:58 5:58 40.8 0.425
Total Fuel: 2.0969999999999995 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631.0 BTU/LB
Comments: Start SOC: 39.9% End SOC: 39.0%