ECG Series

ELKHART COACH, a division of FOREST RIVER, INC. Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2011-11-25
Run Number: 1
Personnel: G.C., E.D. & B.L.
Test Direction: CW
Ambient Temperature (°F): 49
Humidity (%): 77
SLW (lbs): 13580
Wind Speed (mpg) & Direction: 5/W
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:37 8:37 80.3 0.192
ART #1 0 3:55 3:55 80.7 0.186
CBD #2 0 8:28 8:28 81.0 0.188
Art #2 0 3:59 3:59 80.0 0.176
CBD #3 0 8:21 8:21 81.1 0.194
Commuter 0 6:04 6:04 81.6 0.223
Total Fuel: 1.159 SCF
20 minute idle: .121 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631.0 BTU/LB
Comments: None noted.

Date: 2011-11-25
Run Number: 2
Personnel: G.C., E.D. & B.L.
Test Direction: CCW
Ambient Temperature (°F): 56
Humidity (%): 43
SLW (lbs): 13580
Wind Speed (mpg) & Direction: 7/SW
Barometric Pressure (in.Hg): 28
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:17 8:17 78.7 0.193
ART #1 0 3:48 3:48 80.9 0.196
CBD #2 0 8:21 8:21 80.9 0.196
Art #2 0 3:47 3:47 81.5 0.203
CBD #3 0 8:20 8:20 52.6 0.196
Commuter 0 5:53 5:53 83.4 0.235
Total Fuel: 1.2189999999999999 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631.0 BTU/LB
Comments: None noted.

Date: 2011-11-25
Run Number: 3
Personnel: G.C., E.D. & B.L.
Test Direction: CW
Ambient Temperature (°F): 58
Humidity (%): 40
SLW (lbs): 13580
Wind Speed (mpg) & Direction: 10/W
Barometric Pressure (in.Hg): 28
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:25 8:25 83.2 0.188
ART #1 0 4:00 4:00 84.7 0.178
CBD #2 0 7:56 7:56 83.9 0.193
Art #2 0 3:53 3:53 84.3 0.179
CBD #3 0 7:43 7:43 84.1 0.195
Commuter 0 5:56 5:56 83.8 0.231
Total Fuel: 1.1640000000000001 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631.0 BTU/LB
Comments: None noted.

Date: 2011-12-01
Run Number: 4
Personnel: T.W., B.L. & S.c.
Test Direction: CCW
Ambient Temperature (°F): 34
Humidity (%): 74
SLW (lbs): 13580
Wind Speed (mpg) & Direction: 6/WSW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:04 9:04 60.1 0.203
ART #1 0 4:05 4:05 61.5 0.191
CBD #2 0 8:51 8:51 63.3 0.203
Art #2 0 4:08 4:08 62.6 0.19
CBD #3 0 8:48 8:48 63.7 0.201
Commuter 0 6:02 6:02 64.5 0.232
Total Fuel: 1.22 SCF
20 minute idle: .212 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631.0 BTU/LB
Comments: None noted.