Static Towing Test Data Form

Date: 2011-12-19
Personnel: E.L., T.S., J.P., B.L. & E.D.
Temperature: 38

 

Inspect right front tow eye and adjoining structure.
Comments: No damage or deformation observed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Torques verified
Inspect left front tow eye and adjoining structure.
Comments: No damage or deformation observed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Torques verified.
Inspect right rear tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
Inspect left rear tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
General comments of any other structure deformation or failure:
<p>None noted.&nbsp; All 4 front pulls were completed to the target test load of 31,572 lbs. 1.2x26,310 lbs CW.</p>