Orion VII EPA 10 CNG

Daimler Buses North America, LTD Pdf Download PDF Report

Performance Data Form

Date
2011-12-05

Personnel
T.W. & S.C.


Temperature (°F)
42

Humidity (%)
75

Wind Direction
Calm

Wind Speed (mph)
Calm

Barometric Pressure (in.Hg)
30.3

Air Conditioning - OFF Yes
Ventilation Fans - ON HIGH Yes
Heater pump motor - OFF Yes
Defroster - OFF Yes
Exterior and Interior Lights - ON Yes
Windows and Doors - CLOSED Yes

Acceleration, Gradeability, Top Speed

Counter Clockwise Recorded Interval Times
Speed Run 1 Run 2 Run 3
10 mph 4.61 4.7 4.61
20 mph 8.48 8.23 8.51
30 mph 13.54 14.98 14.64
40 mph 26.39 26.61 26.55
Top Test
Speed (50 mph)
38.23 38.51 38.55
Clockwise Recorded Interval Times
Speed Run 1 Run 2 Run 3
10 mph 4.48 4.39 4.94
20 mph 8.29 8.45 8.41
30 mph 14.29 14.27 14.29
40 mph 24.98 24.58 24.85
Top Test
Speed (50 mph)
37.13 35.92 36.1