PS2 President

SUPREME CORPORATION Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2012-01-11
Run Number: 1
Personnel: G.C. & S.C.
Test Direction: CCW
Ambient Temperature (°F): 39
Humidity (%): 64
SLW (lbs): 25150
Wind Speed (mpg) & Direction: 0/
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 7:22 7:22 28.4 0.358
ART #1 0 3:55 3:55 28.3 0.348
CBD #2 0 7:54 7:54 30.3 0.366
Art #2 0 3:55 3:55 30.2 0.344
CBD #3 0 8:01 8:01 32.1 0.354
Commuter 0 6:09 6:09 31.3 0.377
Total Fuel: 2.1470000000000002 SCF
20 minute idle: 0.249 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631.0 BTU/LB
Comments: None noted.

Date: 2012-01-11
Run Number: 2
Personnel: G.C. & S.C.
Test Direction: CW
Ambient Temperature (°F): 39
Humidity (%): 64
SLW (lbs): 25
Wind Speed (mpg) & Direction: 0/
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:22 8:22 28.8 0.344
ART #1 0 3:59 3:59 28.6 0.333
CBD #2 0 8:03 8:03 32.2 0.359
Art #2 0 4:01 4:01 31.8 0.333
CBD #3 0 8:25 8:25 32.1 0.348
Commuter 0 6:14 6:14 32.8 0.386
Total Fuel: 2.103 SCF
20 minute idle: NA SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631 BTU/LB
Comments: None noted.

Date: 2012-01-11
Run Number: 3
Personnel: G.C. & S.C.
Test Direction: CCW
Ambient Temperature (°F): 41
Humidity (%): 64
SLW (lbs): 25150
Wind Speed (mpg) & Direction: 0/
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:24 8:24 32.5 0.34
ART #1 0 3:55 3:55 32.2 0.353
CBD #2 0 8:06 8:06 33.6 0.36
Art #2 0 3:58 3:58 32.6 0.339
CBD #3 0 8:09 8:09 34.1 0.391
Commuter 0 6:03 6:03 33.5 0.391
Total Fuel: 2.174 SCF
20 minute idle: NA SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631 BTU/LB
Comments: None noted.

Date: 2012-01-11
Run Number: 4
Personnel: G.C. & S.C.
Test Direction: CW
Ambient Temperature (°F): 42
Humidity (%): 56
SLW (lbs): 25150
Wind Speed (mpg) & Direction: 6/SSE
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:16 8:16 31.9 0.343
ART #1 0 4:10 4:10 30.7 0.328
CBD #2 0 8:01 8:01 32.0 0.353
Art #2 0 3:54 3:54 32.1 0.337
CBD #3 0 7:55 7:55 32.4 0.359
Commuter 0 6:01 6:01 32.0 0.378
Total Fuel: 2.098 SCF
20 minute idle: 0.271 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19631.0 BTU/LB
Comments: None noted.