PS2 President

SUPREME CORPORATION Pdf Download PDF Report

Static Towing Test Data Form

Date: 2012-01-30
Personnel: B.L. & E.D.
Temperature: 33

 

Inspect right front tow eye and adjoining structure.
Comments: No damage or deformation observed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Torques verified.
Inspect left front tow eye and adjoining structure.
Comments: No damage or deformation observed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Torques verified.
Inspect right rear tow eye and adjoining structure.
Comments: NA
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: NA
Inspect left rear tow eye and adjoining structure.
Comments: NA
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: NA
General comments of any other structure deformation or failure:
<p>All four front pulls were completed to the full target test load of 22,716 lbs (1.2 x 18,930 lbs CW). No damage or deformation was observed.&nbsp; The rear is not equipped with a towing interface therefore a rear test was not performed.</p>