EXCEL 102

BLUE BIRD CORPORATION Pdf Download PDF Report

Static Towing Test Data Form

Date: 2003-04-18
Personnel: S.C., E.D., E.L. and B.T.
Temperature: 44

 

Inspect right front tow eye and adjoining structure.
Comments: Torques verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage or deformation observed.
Inspect left front tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
Inspect right rear tow eye and adjoining structure.
Comments: Torques verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage or deformation observed.
Inspect left rear tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
General comments of any other structure deformation or failure:
No damage or deformation was observed throughout testing. Manufacturer does not recommend towing from the rear. All four front pulls were completed to the full test load of 34212 lbs.