Legacy

GLAVAL BUS/DIV. OF FOREST RIVER Pdf Download PDF Report

Interior Noise Test Data Form

Test Condition 1: 80 dB(A) Stationary White Noise

Date 2011-06-15
Personnel E.D. & T.S.
Temperature (°F) 75
Humidity (%) 41
Wind Direction Variable
Wind Speed (MPH) 3
Barometric Pressure (in.Hg) 30.01
Initial Sound Level Meter Calibration checked by E.D.
Interior Ambient Noise Level dB(A) 34.0
Exterior Ambient Noise Level dB(A) 44.2
Microphone Height During Testing(in) 29
Measurement Location Measured Sound Level dB(A)
Driver's Seat 49.6
Front Passenger Seats 50.9
In Line with Front Speaker 49.5
In Line with Middle Speaker 51.1
In Line with Rear Speaker 50.6
Rear Passenger Seats 49.4
Final Sound Level Meter Calibration checked by E.D.
Comments
<p>All readings taken in the center aisle.</p>