Date Test Miles Service Activity Downtime Hours
08-30-11 1352 Four mounting bolts and grommets are out of the grill causing it to fall off. Grill and mounting bolts and grommets replaced. 1.0 2.0
08-30-11 1352 The brass quarter turn collant valve located by the right front shock is leaking. Brass quarter turn valve tightened. 4.0 2.0
09-07-11 2184 The roof is leaking in the area of the antenna. Leak around antenna sealed. 1.5 1.5
10-05-11 3022 The A/C line through the firewall to the evaporator is leaking refrigerant. Warranty dealer repaired leaking A/C line and added support brackets at the firewall. 296.0 4.0
01-07-12 4600 All 6 tires are worn. All 6 tires replaced. 1.5 4.5
02-10-12 8207 Numerous floor cross member welds are broken or cracked. 8 right side and 8 left side floor cross members welded/repaired. 4.0 4.0