BE-35

PROTERRA, INC. Pdf Download PDF Report

Static Towing Test Data Form

Date: 2012-02-28
Personnel: K.D., E.L. & B.G.
Temperature: 45

 

Inspect right front tow eye and adjoining structure.
Comments: No damage or deformation observed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Welds and boding verified.
Inspect left front tow eye and adjoining structure.
Comments: No damage or deformation observed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Welds and bonding verified.
Inspect right rear tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
Inspect left rear tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
General comments of any other structure deformation or failure:
<p>All four front pulls were completed to the full target test load of 33,216 lbs. (1.2x27,680 lbs CW), with no damage or deformation observed.&nbsp; The manufacturer does not recommend towing from the rear; therefore, a rear test was not performed.</p>