Static Towing Test Data Form
Date:
|
2012-06-05
|
Personnel:
|
B.L., E.D. & E.L.
|
Temperature:
|
54
|
Inspect right front tow eye and adjoining structure. |
Comments:
No damage or deformation observed
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
No damage or deformation observed
|
Inspect left front tow eye and adjoining structure. |
Comments:
No damage or deformation observed
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
Welds inspected
|
Inspect right rear tow eye and adjoining structure. |
Comments:
Not equipped
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
N/A
|
Inspect left rear tow eye and adjoining structure. |
Comments:
Not equipped
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
N/A
|
General comments of any other structure deformation or failure: |
<p>All four front pulls were completed to the full target test load of 38,172 lbs (1.2 X 31,810 lbs CW) with no damage or deformation observed. The manufacturer does not recommend towing from the rear, therefore a row tow was not performed. </p> |
|
|
General
Check-In
Maintainability
Repair & Maintenance
Replacement & Repair
Reliability
Safety
Performance
Structural
Fuel Economy
Noise
Glossary