XN60

NEW FLYER Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2012-11-02
Run Number: 1
Personnel: B.L., E.D. & S.R.
Test Direction: CW
Ambient Temperature (°F): 41
Humidity (%): 61
SLW (lbs): 50
Wind Speed (mpg) & Direction: 10/W
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:46 8:46 73.0 91.2
ART #1 0 4:12 4:12 74.0 72.7
CBD #2 0 8:50 8:50 71.7 90.9
Art #2 0 4:14 4:14 73.3 72.6
CBD #3 0 8:49 8:49 71.3 92.9
Commuter 0 6:01 6:01 73.6 100.8
Total Fuel: 521.0999999999999 SCF
20 minute idle: 57.9 SCF
No Load Flow Rate at Idle = 2.98 SCFM No Load Flow Rate at Full Throttle = 13.33 SCFM
Heating Value = 1,008.1 BTU/LB
Comments: None Noted

Date: 2012-11-02
Run Number: 2
Personnel: B.L., E.D., S.R. & T.S.
Test Direction: CCW
Ambient Temperature (°F): 41
Humidity (%): 60
SLW (lbs): 50
Wind Speed (mpg) & Direction: 9/W
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:46 8:46 61.2 94.8
ART #1 0 4:11 4:11 68.4 74.6
CBD #2 0 8:48 8:48 68.5 92.8
Art #2 0 4:12 4:12 74.4 73.9
CBD #3 0 8:48 8:48 72.8 92.5
Commuter 0 6:01 6:01 76.4 100.7
Total Fuel: 529.3000000000001 SCF
20 minute idle: N/A SCF
No Load Flow Rate at Idle = N/A SCFM No Load Flow Rate at Full Throttle = N/A SCFM
Heating Value = 1,008.1 BTU/LB
Comments: None Noted

Date: 2012-11-02
Run Number: 3
Personnel: B.L., E.D., S.R. & T.S.
Test Direction: CW
Ambient Temperature (°F): 43
Humidity (%): 48
SLW (lbs): 50
Wind Speed (mpg) & Direction: 10/NW
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:55 8:55 75.1 90.0
ART #1 0 4:16 4:16 75.8 73.2
CBD #2 0 8:53 8:53 73.5 88.7
Art #2 0 4:14 4:14 76.3 75.0
CBD #3 0 8:48 8:48 74.5 93.6
Commuter 0 6:05 6:05 77.1 101.9
Total Fuel: 522.4 SCF
20 minute idle: N/A SCF
No Load Flow Rate at Idle = N/A SCFM No Load Flow Rate at Full Throttle = N/A SCFM
Heating Value = 1,008.1 BTU/LB
Comments: None Noted

Date: 2012-11-02
Run Number: 4
Personnel: B.L., E.D., S.R. & T.S.
Test Direction: CCW
Ambient Temperature (°F): 45
Humidity (%): 45
SLW (lbs): 50
Wind Speed (mpg) & Direction: 10/NW
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:49 8:49 76.6 87.5
ART #1 0 4:13 4:13 77.4 70.0
CBD #2 0 8:49 8:49 75.3 84.2
Art #2 0 4:14 4:14 78.1 67.2
CBD #3 0 8:44 8:44 76.7 83.4
Commuter 0 6:03 6:03 78.4 93.9
Total Fuel: 486.19999999999993 SCF
20 minute idle: 63.8 SCF
No Load Flow Rate at Idle = 2.29 SCFM No Load Flow Rate at Full Throttle = 13.59 SCFM
Heating Value = 1008.1 BTU/LB
Comments: None Noted